NOTICE DATE: August 7, 2024
NOTICE TYPE: M-B072324-02 NPRR
SHORT DESCRIPTION: Implementation Details for NPRRs 1058, 1131, and OBDRR 040
INTENDED AUDIENCE: All Market Participants
DAYS AFFECTED: August 23, 2024
LONG DESCRIPTION: On August 23, 2024, Protocol language associated with Nodal Protocol Revision Request (NPRR) 1058, Resource Offer Modernization, NPRR 1131, Controllable Load Participation in Non-Spin, and Other Binding Document Revision Request (OBDRR) 040, ORDC Changes Related to NPRR 1131, Controllable Load Participation in Non-Spin, will be implemented.
NPRR1058 allows all Resources to update their energy bids and offers within the Operating Period in Real-Time. Paragraph (4) of Protocol Section 4.4.9.3, Energy Offer Curve Cost Caps, requires a Qualified Scheduling Entity (QSE) to submit a reason for the update if the market submission is submitted within the Operating Period (i.e., after the end of the Adjustment Period). Per NPRR1058, the submission of a reason is required for all Resource.
NPRR1131 changes Controllable Load Resource participating in Non-Spinning Reserve Service (Non-Spin) from Off-Line to On-Line Non-Spin. Consistent with On-Line treatment, this NPRR also sets a bid floor of $75/ MWh for Controllable Load Resource capacity providing Non-Spin, equivalent to the offer floor for Generation Resources providing On-Line Non-Spin and adds the requirement that if the Qualified Scheduling Entity (QSE) also assigns Responsive Reserve Service (RRS) and/or Regulation Up Service (Reg-Up) to a Controllable Load Resource that has been assigned Non-Spin, there will be a bid floor for the sum of the RRS, Reg-Up, and Non-Spin Ancillary Service Resource Responsibilities of $75/MWh.
OBDRR040 supports the implementation of NPRR 1131 by removing Controllable Load Resources providing Non-Spin schedules and Regulation Service schedules from the Operating Reserve Demand Curve (ORDC) capacity calculations. in alignment with the standing deployment under NPRR1131.
ADDITIONAL INFORMATION: Pursuant to Nodal Protocol Section 21.6, Nodal Protocol Revision Implementation, ERCOT is required to provide notice as soon as practicable, but no later than ten days prior to implementation.
NPRR1058, NPRR1131, and OBDRR040 and their associated documents can be found on the ERCOT website.
Please review the ERCOT website for previous market notices related to this subject:
CONTACT: If you have any questions, please contact your ERCOT Account Manager. You may also call the general ERCOT Client Services phone number at (512) 248-3900 or contact ERCOT Client Services via email at ClientServices@ercot.com.