NPRR1019

Summary

Title Pricing and Settlement Changes for Switchable Generation Resources (SWGRs) Instructed to Switch to ERCOT
Next Group
Next Step
Status Approved on 06/09/2020
Effective Dates
06/10/2020

Sections 3.9.1, 6.6.12, 6.6.12.1, and paragraph (4)(e)(iv) of Section 6.5.7.3

Action

Date Gov Body Action Taken Next Steps
06/09/2020 BOARD Approved
05/29/2020 TAC Recommended for Approval Revision Request Consideration
05/15/2020 PRS Recommended for Approval Revision Request Consideration
04/20/2020 PRS Recommended for Approval Impact Analysis Consideration

Voting Record

Date Gov Body Motion Result
06/09/2020 BOARD to approve NPRR1019 as recommended by TAC in the 5/29/20 TAC Report as amended by the 6/1/20 ERCOT comments Passed
05/29/2020 TAC to recommend approval of NPRR1019 as recommended by PRS in the 5/15/20 PRS Report Passed
05/15/2020 PRS to grant NPRR1019 Urgent status, and to endorse and forward to TAC the 4/20/20 PRS Report and Impact Analysis for NPRR1019 with a recommended effective date of upon ERCOT Board approval for Sections 3.9.1, 6.6.12, 6.6.12.1, and paragraphs (4)(e)(iii)-(vi) of Section 6.5.7.3 and a recommended priority of 2020 and rank of 3030 for the remaining language Passed
04/20/2020 PRS to recommend approval of NPRR1019 as amended by the 4/9/20 GSEC comments Passed

Background

Status: Approved
Date Posted: Apr 1, 2020
Sponsor: ERCOT
Urgent: Yes
Sections: 3.9.1, 6.4.4.2 (delete), 6.5.7.3, 6.6.12, and 6.6.12.1
Description: This NPRR addresses the switching of Switchable Generation Resources (SWGRs) from a non-ERCOT Control Area to the ERCOT the Control Area. Specifically, this NPRR makes the following changes: • Proposes that ERCOT systems automatically create a proxy Energy Offer Curve with a price floor of $4,500/MWh for each Reliability Unit Commitment (RUC)-committed SWGR as opposed to requiring Qualified Scheduling Entities (QSEs) to submit Energy Offer Curves reflecting the $4,500/MWh floor. • Includes a lost revenue cost component to the Switchable Generation Cost Guarantee (SWCG) to ensure that Combined-Cycle Generation Resource SWGRs are made whole to their costs when switching from a non-ERCOT Control Area to the ERCOT Control Area.