NOGRR245
Summary
Title | Inverter-Based Resource (IBR) Ride-Through Requirements |
---|---|
Next Group | BOARD |
Next Step | Revision Request Consideration |
Status | Pending |
Action
Date | Gov Body | Action Taken | Next Steps |
---|---|---|---|
06/18/2024 | BOARD | Deferred/Tabled | Revision Request Consideration |
06/07/2024 | TAC | Recommended for Approval | Revision Request Consideration |
05/22/2024 | TAC | Deferred/Tabled | Revision Request Consideration |
04/23/2024 | BOARD | Remanded | Revision Request Consideration |
03/27/2024 | TAC | Recommended for Approval | Revision Request Consideration |
09/26/2023 | TAC | Deferred/Tabled | Revision Request Consideration |
09/14/2023 | ROS | Recommended for Approval | Revision Request Consideration |
02/08/2023 | ROS | Deferred/Tabled | Language Consideration |
Voting Record
Date | Gov Body | Motion | Result |
---|---|---|---|
06/18/2024 | BOARD | to table NOGRR245 | Passed |
06/07/2024 | TAC | to recommend approval of NOGRR245 as recommended by TAC in the 3/27/24 TAC Report as amended by the 6/5/24 ERCOT comments as revised by TAC | Passed |
05/22/2024 | TAC | to table NOGRR245 | Passed |
04/23/2024 | BOARD | to remand NOGRR245 to TAC | Passed |
03/27/2024 | TAC | to recommend approval of NOGRR245 as recommended by ROS in the 9/14/23 ROS Report as amended by the 3/22/24 Joint Commenters 2 comments as revised by TAC | Passed |
09/26/2023 | TAC | to table NOGRR245 | Passed |
09/14/2023 | ROS | to grant NOGRR245 Urgent status; to recommend approval of NOGRR245 as amended by the 9/13/23 NextEra comments as revised by ROS; and to forward to TAC NOGRR245 and the 1/11/23 Impact Analysis | Passed |
02/08/2023 | ROS | to table NOGRR245 and refer the issue to the Operations Working Group (OWG), Dynamics Working Group (DWG) and Inverter-Based Resource Task Force (IBRTF) | Passed |
Background
Status: | Pending |
---|---|
Date Posted: | Jan 11, 2023 |
Sponsor: | ERCOT |
Urgent: | Yes |
Sections: | 2.6.2, 2.6.2.1, 2.6.2.1.1 (new), 2.6.4 (new), 2.9, 2.9.1, 2.9.1.1 (new), 2.9.1.2 (new), 2.11 (new), 2.11.1(new), 2.11.2 (new) 2.12 (new), 2.12.1 (new), 2.12.2 (new), 2.12.3 (new), 2.12.1.4 (new), 2.12.3 (new), 2.13 (new), 2.13.1 (new), 2.13.1.1 (new), 2.13.1.2 (new), 2.13.1.3 (new), 2.13.1.4 (new), 2.13.1.4.1 (new), 2.14 (new) |
Description: | This Nodal Operating Guide Revision Request (NOGRR) replaces the current voltage ride-through requirements for Intermittent Renewable Resources (IRRs) with voltage ride-through requirements for Inverter-Based Resources (IBRs) and Type 1 and Type 2 Wind-powered Generation Resources (WGRs) and provides new frequency ride-through requirements for IBRs and Type 1 and 2 WGRs consistent with or beyond requirements identified in the new 2800-2022 - Institute of Electrical and Electronics Engineers (IEEE) Standard for Interconnection and Interoperability of Inverter-Based Resources (IBRs) Interconnecting with Associated Transmission Electric Power Systems (“IEEE 2800-2022 standard”). |
Reason: | Strategic Plan Objective 1 |
Key Documents
Jan 11, 2023 - docx - 372.1 KB
Jan 11, 2023 - docx - 32 KB
Feb 10, 2023 - xls - 147 KB
Feb 10, 2023 - docx - 376 KB
Feb 16, 2023 - doc - 284 KB
Feb 17, 2023 - docx - 361.2 KB
Mar 7, 2023 - docx - 360.2 KB
Mar 20, 2023 - docx - 362.8 KB
Apr 5, 2023 - docx - 368.4 KB
Apr 26, 2023 - doc - 48.5 KB
May 1, 2023 - docx - 35.4 KB
May 1, 2023 - docx - 543 KB
May 2, 2023 - doc - 86.5 KB
May 3, 2023 - doc - 44.5 KB
May 3, 2023 - docx - 25 KB
May 3, 2023 - docx - 24.4 KB
May 3, 2023 - doc - 42.5 KB
May 17, 2023 - docx - 37.3 KB
Jun 6, 2023 - doc - 80.5 KB
Jun 7, 2023 - pdf - 180 KB
Jun 16, 2023 - docx - 37.6 KB
Jun 22, 2023 - docx - 394.1 KB
Jun 22, 2023 - doc - 48 KB
Jul 26, 2023 - doc - 43 KB
Jul 28, 2023 - docx - 35.3 KB
Jul 28, 2023 - docx - 39.9 KB
Jul 31, 2023 - doc - 52.5 KB
Jul 31, 2023 - docx - 27.2 KB
Jul 31, 2023 - doc - 1.4 MB
Jul 31, 2023 - docx - 71.8 KB
Aug 2, 2023 - docx - 48.5 KB
Aug 2, 2023 - doc - 57.5 KB
Aug 3, 2023 - docx - 35.6 KB
Aug 11, 2023 - docx - 29 KB
Aug 18, 2023 - docx - 438.2 KB
Sep 4, 2023 - docx - 67.5 KB
Sep 5, 2023 - docx - 453.2 KB
Sep 5, 2023 - docx - 388 KB
Sep 5, 2023 - docx - 195.3 KB
Sep 6, 2023 - docx - 66.3 KB
Sep 11, 2023 - doc - 56 KB
Sep 13, 2023 - docx - 187 KB
Sep 13, 2023 - doc - 42.5 KB
Sep 13, 2023 - doc - 50 KB
Sep 19, 2023 - xls - 140 KB
Sep 19, 2023 - docx - 430.9 KB
Sep 22, 2023 - docx - 114.9 KB
Sep 24, 2023 - docx - 58.1 KB
Sep 25, 2023 - docx - 33.2 KB
Sep 28, 2023 - xls - 140 KB
Sep 28, 2023 - docx - 438.6 KB
Sep 29, 2023 - docx - 29.3 KB
Oct 16, 2023 - doc - 68 KB
Oct 23, 2023 - docx - 57.7 KB
Oct 23, 2023 - docx - 34.5 KB
Oct 30, 2023 - docx - 75.9 KB
Nov 1, 2023 - doc - 75 KB
Nov 7, 2023 - doc - 78.5 KB
Dec 2, 2023 - docx - 33 KB
Dec 2, 2023 - docx - 57.8 KB
Jan 8, 2024 - docx - 552.1 KB
Jan 11, 2024 - docx - 35.8 KB
Jan 19, 2024 - docx - 490.4 KB
Jan 23, 2024 - docx - 34 KB
Jan 23, 2024 - docx - 440.4 KB
Jan 23, 2024 - docx - 26.8 KB
Feb 12, 2024 - docx - 64.8 KB
Mar 20, 2024 - docx - 426.3 KB
Mar 22, 2024 - docx - 328.8 KB
Mar 26, 2024 - docx - 104.5 KB
Apr 1, 2024 - xls - 140.5 KB
Apr 1, 2024 - docx - 337.7 KB
Apr 15, 2024 - docx - 34.2 KB
Apr 15, 2024 - pdf - 293.6 KB
Apr 15, 2024 - docx - 106.2 KB
Apr 15, 2024 - docx - 353 KB
Apr 24, 2024 - docx - 338.7 KB
May 23, 2024 - xls - 144 KB
May 23, 2024 - docx - 339 KB
Jun 5, 2024 - docx - 336.2 KB
Jun 6, 2024 - docx - 334.9 KB
Jun 6, 2024 - docx - 331.4 KB
Jun 10, 2024 - xls - 144 KB
Jun 10, 2024 - docx - 367.8 KB
Jun 10, 2024 - docx - 34.4 KB
Jun 10, 2024 - pdf - 365.4 KB
Jun 11, 2024 - pdf - 584.9 KB
Jun 11, 2024 - pdf - 560.2 KB
Jun 11, 2024 - pdf - 585.5 KB
Jun 11, 2024 - pdf - 561.9 KB
Jun 11, 2024 - pdf - 586 KB
Jun 11, 2024 - pdf - 585.7 KB
Jun 11, 2024 - pdf - 585.9 KB
Jun 11, 2024 - pdf - 132.1 KB
Jun 11, 2024 - pdf - 585.9 KB
Jun 11, 2024 - pdf - 562.3 KB
Jun 11, 2024 - pdf - 562.1 KB
Jun 11, 2024 - pdf - 586.6 KB
Jun 11, 2024 - pdf - 562.1 KB
Jun 11, 2024 - pdf - 562.2 KB
Jun 11, 2024 - pdf - 562.4 KB
Jun 11, 2024 - pdf - 562.1 KB
Jun 11, 2024 - pdf - 562.1 KB
Jun 11, 2024 - pdf - 562.2 KB
Jun 16, 2024 - docx - 87.2 KB
Jun 20, 2024 - docx - 369 KB