- Home
- Market Rules
- Issues
NPRR086
Summary
Title | Settlement Clarifications to RUC Capacity Shortfall Ratio Share Formula |
---|---|
Next Group | |
Next Step | |
Status | Approved on 01/15/2008 |
Effective Dates |
12/01/2010
or per the Nodal Protocol Transition Plan http://www.ercot.com/mktrules/protocols (02/01/08 Nodal Protocols Library) |
Action
Date | Gov Body | Action Taken | Next Steps |
---|---|---|---|
01/15/2008 | BOARD | Approved | |
01/03/2008 | TAC | Recommended for Approval | Board consideration |
12/13/2007 | PRS | Recommended for Approval | |
11/15/2007 | PRS | Recommended for Approval |
Voting Record
Date | Gov Body | Motion | Result |
---|---|---|---|
01/15/2008 | BOARD | To approve as recommended by TAC. | Passed |
01/03/2008 | TAC | Recommended for approval as revised by TAC. | Passed |
12/13/2007 | PRS | To forward the Recommendation Report and IA to TAC for approval | Passed |
11/15/2007 | PRS | To recommend approval of NPRR086 as submitted | Passed |
Background
Status: | Approved |
---|---|
Date Posted: | Oct 25, 2007 |
Sponsor: | TPTF |
Urgent: | No |
Sections: | 5.7.1.1, RUC Guarantee; 5.7.1.2, RUC Minimum-Energy Revenue; 5.7.1.3, Revenue Less Cost Above LSL During RUC-Committed Hours; 5.7.1.4, Revenue Less Cost During QSE Clawback Intervals; 5.7.3, Payment When ERCOT Decommits a QSE -Committed Resource; and 5.7.4.1.1, Capacity Shortfall Ratio Share |
Description: | This NPRR revises Section 5.6.4.1.1 to clarify that the Capacity Shortfall Ratio Share includes DC Tie imports and exports; modifies the definition of the variable HASLADJ (High Ancillary Service Limit) used in calculating the Reliability Unit Commitment (RUC) Capacity Shortfall Ratio Share in Section 5.7.4. ; and modifies the definition of the variable LSL to reflect that its value is the same as the Low Sustained Limit (LSL) in the Current Operating Plan (COP). |
Reason: | The current language in Section 5.7.4.1.1 does not include DC Tie imports and exports when calculating the Qualified Scheduling Entity’s (QSE’s) Capacity at each RUC process. The inclusion of DC Tie activity is necessary to correctly reflect each QSE’s Capacity at each RUC process as specified in paragraph (3) of Section 4.4.4, DC Tie Schedules. Also, the current variable definition of ‘HASLADJ’ in Section 5.7.4, RUC Make Whole Charges, includes a specific concept that would be better presented be in a separate paragraph rather than the variable description.In addition, the definition of LSL in Section 5 needs clarification that the LSL value used in the RUC calculations will come from the COP and is not the telemetered value. |
Key Documents
Oct 15, 2007 - xls - 114.5 KB
Oct 25, 2007 - doc - 280 KB
Nov 19, 2007 - doc - 270.5 KB
Dec 12, 2007 - doc - 49.5 KB
Dec 17, 2007 - doc - 272.5 KB
Jan 4, 2008 - doc - 276.5 KB
Jan 15, 2008 - doc - 279.5 KB