- Home
- Market Rules
- Issues
NPRR598
Summary
Title | Clarify Inputs to PRC and ORDC |
---|---|
Next Group | |
Next Step | |
Status | Approved on 04/08/2014 |
Effective Dates |
05/01/2014
|
Action
Date | Gov Body | Action Taken | Next Steps |
---|---|---|---|
04/08/2014 | BOARD | Approved | |
02/27/2014 | TAC | Recommended for Approval | ERCOT Board for consideration |
02/13/2014 | PRS | Recommended for Approval | TAC for consideration |
Voting Record
Date | Gov Body | Motion | Result |
---|---|---|---|
04/08/2014 | BOARD | To approved NPRR598 as amended by the 3/28/14 TAC comments. | Passed |
02/27/2014 | TAC | To recommend approval of NPRR598 as recommended by PRS in the 2/13/14 PRS Report and as amended by the 2/25/14 ERCOT comments; to recommend approval of the "Methodology for Implementing Operating Reserve Demand Curve (ORDC) to Calculate Real-Time Reserve Price Adder" as amended by the 2/25/14 ERCOT comments - Attachment 1; and to add the methodology to the Other Binding Document List. | Passed |
02/13/2014 | PRS | To recommend approval of NPRR598 as submitted and to forward it and the Impact Analysis to TAC. | Passed |
Background
Status: | Approved |
---|---|
Date Posted: | Feb 12, 2014 |
Sponsor: | ERCOT |
Urgent: | Yes |
Sections: | 6.5.7.3, 6.5.7.5, 6.7.4 |
Description: | This Nodal Protocol Revision Request (NPRR) aligns the inputs to Physical Responsive Capability (PRC) and ORDC; stipulates the treatment of Off-Line capacity during scarcity conditions; and also proposes the following changes: · Removes STARTUP and SHUTDOWN status from PRC and ORDC calculations; · Sets Real-Time Off-Line available reserves used in the ORDC calculation to zero when SCED snapshot of the PRC becomes less than or equal to 2,300 MW which is the PRC MW at which Energy Emergency Alert (EEA) Level 1 is initiated; and · Changes the Load Resource Responsive Reserve (RRS) schedule used in ORDC to Max { min{Telemetered MW, RRS schedule, max[MPC - LPC - (Regulation responsibility + Non-Spin responsibility + Down Regulation responsibility), 0]}, 0} |
Reason: | Market efficiencies or enhancements |
Key Documents
Feb 12, 2014 - doc - 414.5 KB
Feb 12, 2014 - doc - 55 KB
Feb 12, 2014 - doc - 3.4 MB
Feb 19, 2014 - doc - 424 KB
Feb 24, 2014 - doc - 38.5 KB
Feb 26, 2014 - doc - 378 KB
Feb 26, 2014 - doc - 7.8 MB
Mar 3, 2014 - doc - 442.5 KB
Mar 3, 2014 - doc - 7.8 MB
Mar 18, 2014 - doc - 7.8 MB
Mar 26, 2014 - doc - 7.8 MB
Mar 26, 2014 - doc - 7.8 MB
Mar 28, 2014 - doc - 390.5 KB
Mar 28, 2014 - doc - 7.8 MB
Mar 31, 2014 - doc - 7.8 MB
Apr 4, 2014 - doc - 7.8 MB
Apr 8, 2014 - doc - 447 KB
Apr 8, 2014 - doc - 7.8 MB