- Home
- Market Rules
- Issues
NPRR849
Summary
Title | Clarification of the Range of Voltage Set Points at a Generation Resource’s POI |
---|---|
Next Group | |
Next Step | |
Status | Approved on 12/10/2019 |
Effective Dates |
01/01/2020
|
Action
Date | Gov Body | Action Taken | Next Steps |
---|---|---|---|
12/10/2019 | BOARD | Approved | |
10/23/2019 | TAC | Recommended for Approval | Board for consideration |
10/10/2019 | PRS | Recommended for Approval | TAC for consideration |
09/12/2019 | PRS | Recommended for Approval | PRS for Impact Analysis consideration |
10/12/2017 | PRS | Deferred/Tabled | PRS for consideration |
Voting Record
Date | Gov Body | Motion | Result |
---|---|---|---|
12/10/2019 | BOARD | To approve NPRR849 as recommended by TAC in the 10/23/19 TAC Report | Passed |
10/23/2019 | TAC | To recommend approval of NPRR849 as recommended by PRS in the 10/10/19 PRS Report as amended by the 10/22/19 ERCOT comments | Passed |
10/10/2019 | PRS | To endorse and forward to TAC the 9/12/19 PRS Report and Impact Analysis for NPRR849 | Passed |
09/12/2019 | PRS | To recommend approval of NPRR849 as amended by the 9/11/19 ERCOT comments | Passed |
10/12/2017 | PRS | To table NPRR849 and refer the issue to ROS | Passed |
Background
Status: | Approved |
---|---|
Date Posted: | Sep 27, 2017 |
Sponsor: | ERCOT |
Urgent: | No |
Sections: | 3.15 |
Description: | This Nodal Protocol Revision Request (NPRR) revises Section 3.15 to clarify the range of voltages at the Point of Interconnection (POI) and circumstances for which a Generation Resource’s reactive capability must be designed to meet. This NPRR does not modify any other provisions within Section 3.15 or its subsections; does not change the Generation Resource’s responsibility to adhere to Voltage Set Points; and does not modify the 2% tolerance band identified in paragraph (4) of Nodal Operating Guide Section 2.7.3.5, Resource Entity Responsibilities and Generation Resource Requirements. Rather, this NPRR simply aims to more clearly specify the reactive capability the Generation Resource must be designed to provide. |
Reason: | Addresses current operational issues |
Key Documents
Sep 27, 2017 - doc - 105.5 KB
Sep 27, 2017 - doc - 56.5 KB
Oct 5, 2017 - doc - 261 KB
Oct 16, 2017 - doc - 111.5 KB
Nov 3, 2017 - doc - 40.5 KB
Dec 4, 2017 - doc - 64.5 KB
Jan 25, 2018 - doc - 49.5 KB
Apr 9, 2018 - doc - 50 KB
Jun 21, 2018 - doc - 63 KB
Sep 7, 2018 - doc - 46 KB
Sep 18, 2018 - doc - 66.5 KB
Oct 25, 2018 - docx - 74.2 KB
Jan 22, 2019 - docx - 76.4 KB
Apr 24, 2019 - docx - 76.3 KB
Apr 25, 2019 - docx - 28.9 KB
Jun 21, 2019 - docx - 30.1 KB
Jul 3, 2019 - docx - 34.2 KB
Jul 11, 2019 - doc - 63.5 KB
Jul 16, 2019 - doc - 69.5 KB
Sep 11, 2019 - doc - 82.5 KB
Sep 17, 2019 - doc - 144.5 KB
Oct 14, 2019 - doc - 141.5 KB
Oct 22, 2019 - doc - 89 KB
Oct 29, 2019 - doc - 144.5 KB
Dec 11, 2019 - doc - 146.5 KB