- Home
- Market Rules
- Issues
OGRR223
Summary
Title | Real Time Production Potential |
---|---|
Next Group | |
Next Step | |
Status | Approved on 01/06/2010 |
Action
Date | Gov Body | Action Taken | Next Steps |
---|---|---|---|
01/06/2010 | TAC | Approved | |
11/05/2009 | TAC | Referred | WMS Review |
10/15/2009 | ROS | Recommended for Approval | TAC Consideration |
09/15/2009 | OWG | Recommended for Approval | ROS Consideration |
08/19/2009 | OWG | Deferred/Tabled | OWG IA Review |
07/27/2009 | OWG | Recommended for Approval | OWG IA review |
06/17/2009 | OWG | Deferred/Tabled | OWG Consideration |
05/20/2009 | OWG | Deferred/Tabled | OWG Consideration |
Voting Record
Date | Gov Body | Motion | Result |
---|---|---|---|
01/06/2010 | TAC | To approve OGRR223 as recommended by ROS in the 10/15/09 ROS Recommendation Report and as revised by TAC | Passed |
11/05/2009 | TAC | To refer OGRR223 to WMS | Passed |
10/15/2009 | ROS | To recommend approval of OGRR223 as recommended by the OWG in the 9/15/09 OWG Recommendation Report. | Passed |
09/15/2009 | OWG | Consensus to forward the 8/19/09 OWG Recommendation Report and Impact Analysis to ROS | |
08/19/2009 | OWG | Consensus to table OGRR223 for one month | |
07/27/2009 | OWG | Consensus to recommend approval of OGRR223 as submitted. | |
06/17/2009 | OWG | Consensus to table OGRR223 for one month. | |
05/20/2009 | OWG | Consensus to table OGRR223 for one month. |
Background
Status: | Approved |
---|---|
Date Posted: | Apr 17, 2009 |
Sponsor: | Wind Coalition |
Urgent: | No |
Sections: | Attachment 8A: ERCOT Data Sets |
Description: | This Operating Guide Revision Request (OGRR) establishes a requirement for Wind-powered Generation Resources (WGRs) to telemeter a Real Time signal indicating the Real Time Production Potential (RTPP) which will be a function of wind and turbine availability at the time. |
Reason: | To provide ERCOT with information about the actual available wind generation for curtailed WGRs as well as additional information to tune the wind generation forecast models. |
Key Documents
Apr 17, 2009 - doc - 284.5 KB
May 19, 2009 - doc - 42 KB
May 22, 2009 - doc - 291 KB
Jun 15, 2009 - doc - 40.5 KB
Jun 22, 2009 - doc - 292 KB
Jul 22, 2009 - doc - 38.5 KB
Jul 28, 2009 - doc - 291.5 KB
Aug 31, 2009 - doc - 147.5 KB
Aug 20, 2009 - doc - 56 KB
Aug 24, 2009 - doc - 293 KB
Aug 31, 2009 - doc - 140.5 KB
Sep 2, 2009 - doc - 43.5 KB
Sep 16, 2009 - doc - 296 KB
Oct 19, 2009 - doc - 299 KB
Nov 6, 2009 - doc - 300.5 KB
Jan 8, 2010 - doc - 301.5 KB