- Home
- Market Rules
- Issues
SMOGRR019
Summary
Title | Clarifications and Updates to Paralleling Current Transformers, Instrument Transfer Name Plate Photos and Loss Potential Event Logging Requirements |
---|---|
Next Group | |
Next Step | |
Status | Approved on 12/01/2016 |
Effective Dates |
01/01/2018
Paragraph (1)(k) of Section 6.5.4 01/01/2017
All sections except for Section 6.5.4(1)(k) |
Action
Date | Gov Body | Action Taken | Next Steps |
---|---|---|---|
12/01/2016 | TAC | Approved | |
11/02/2016 | WMS | Recommended for Approval | Revision Request Consideration |
10/20/2016 | MWG | Recommended for Approval | Revision Request Consideration |
09/22/2016 | MWG | Recommended for Approval | MWG for Impact Analysis review |
Voting Record
Date | Gov Body | Motion | Result |
---|---|---|---|
12/01/2016 | TAC | To approve SMOGRR019 as recommended by WMS in the 11/2/16 WMS Report. | Passed |
11/02/2016 | WMS | To recommend approval of SMOGRR019 as recommended by MWG in the 10/20/16 MWG Report. | Passed |
10/20/2016 | MWG | To endorse and forward to WMS the 9/22/16 MWG Report and Impact Analysis for SMOGRR019 with a recommendation that revisions to paragraph (k) of Section 6.5.4 be implemented 1/1/18, and for all other revision to be implemented upon TAC approval. | Passed |
09/22/2016 | MWG | To recommend approval of SMOGRR019 as revised by MWG | Passed |
Background
Status: | Approved |
---|---|
Date Posted: | Sep 2, 2016 |
Sponsor: | ERCOT |
Urgent: | No |
Sections: | 1.3.7, 1.4.7, 3.2.3, 6.5.4 |
Description: | This Settlement Metering Operating Guide Revision Request (SMOGRR): 1. Clarifies paragraph (e) of Section 1.3.7 with regard to connected burden, 2. Deletes Section 1.4.7, 3. Modifies Section 3.2.3 to require the submission of nameplate photographs for new or replacement instrument transformers as part of site certification package, and 4. Modifies Section 6.5.4 to specify the voltage levels for logging loss of potential events. Note: The changes in paragraph (k) of Section 6.5.4 would be grey boxed and not implemented until one year after approval to allow Transmission and/or Distribution Service Providers (TDSPs) to reprogram ERCOT Polled Settlement (EPS) meters during the annual meter tests. This delayed implementation date, and having work performed during normal activities, will minimize impact to both TDSPs and ERCOT metering operations staff for this change. |
Reason: | Addresses current operational issues; Market efficiencies or enhancements |
Key Documents
Oct 18, 2016 - doc - 56.5 KB
Sep 23, 2016 - doc - 107 KB
Oct 24, 2016 - doc - 109 KB
Nov 7, 2016 - doc - 111 KB
Dec 5, 2016 - doc - 112.5 KB