MIS LOG IN

Public Notices

This section contains public market notifications required by protocols as well as other market messages ERCOT may post for market transparency. ERCOT began archiving public notices November 3, 2011.

Apr 2024 May 2024 Jun 2024 Jul 2024 Aug 2024 Sep 2024
Date & Time Notice Type Status
Aug 31, 2024 5:20:32 PM ERCOT has cancelled the following notice: ERCOT has been notified that the Railroad DC Tie has been derated to 150MW Import/Export due to breaker trip until further notice. Operational Information Cancelled
Aug 31, 2024 8:46:34 AM The Daily RSASM for 08/31/2024 will not be occurring due to zero participating QSEs. Operational Information Active
Aug 31, 2024 1:54:36 AM ERCOT has cancelled the following notice: ERCOT will execute a SASM at [0135] for operating day 08/31/2024 for 15MW RRS for HE 04 – HE 08 for each hour. Operational Information Cancelled
Aug 31, 2024 1:02:11 AM ERCOT will execute a SASM at [0135] for operating day 08/31/2024 for 15MW RRS for HE 04 – HE 08 for each hour. Operational Information Active
Aug 31, 2024 12:31:25 AM ERCOT has been notified that the Railroad DC Tie has been derated to 150MW Import/Export due to breaker trip until further notice. Operational Information Active
Aug 31, 2024 12:13:04 AM On August 30, 2024, a sudden loss of generation occurred at 19:49 totaling 632 MW. Frequency declined to 59.943 Hz, ERCOT load was 67101 MW. Operational Information Active
Aug 30, 2024 8:46:24 AM The Daily RSASM for 08/30/2024 will not be occurring due to zero participating QSEs. Operational Information Active
Aug 30, 2024 12:21:51 AM No sudden loss of generation greater than 450 MW occurred on August 29, 2024. Operational Information Active
Aug 29, 2024 8:46:36 AM The Daily RSASM for 08/29/2024 will not be occurring due to zero participating QSEs. Operational Information Active
Aug 29, 2024 12:15:28 AM No sudden loss of generation greater than 450 MW occurred on August 28, 2024. Operational Information Active
Aug 28, 2024 8:31:12 PM Cancelled RUC commitment at 1942 on 8/28/24 for Brauning VHB2 for 8/29/24 for HE 17 thorough HE 22 due to unintended commitment. Cancelled RUC commitment at 1946 on 8/28/24 for GRSES Unit 1 for 8/29/24 for HE 20 due to unintended commitment. Operational Information Active
Aug 28, 2024 8:45:55 AM The Daily RSASM for 08/28/2024 will not be occurring due to zero participating QSEs. Operational Information Active
Aug 28, 2024 12:45:56 AM No sudden loss of generation greater than 450 MW occurred on August 27, 2024. Operational Information Active
Aug 27, 2024 8:45:45 AM The Daily RSASM for 08/27/2024 will not be occurring due to zero participating QSEs. Operational Information Active
Aug 27, 2024 12:17:43 AM On August 26, 2024, a sudden loss of generation occurred at 14:38 totaling 768 MW. Frequency declined to 59.940 Hz, ERCOT load was 74,171 MW. Operational Information Active
Aug 26, 2024 8:45:57 AM The Daily RSASM for 08/26/2024 will not be occurring due to zero participating QSEs. Operational Information Active
Aug 26, 2024 12:01:09 AM No sudden loss of generation greater than 450 MW occurred on August 25, 2024. Operational Information Active
Aug 25, 2024 10:04:45 AM ERCOT has cancelled the following notice: The SASM scheduled for 09:40 has been changed to execute 0950 for operating day 08/25/24 for HE 12-24 for 38 MW of ECRS for each hour. Operational Information Cancelled
Aug 25, 2024 10:04:39 AM ERCOT has cancelled the following notice: ERCOT will execute a SASM at 0940 for operating day 08/25/24 for HE 12-24 for 38 MW of ECRS for each hour. Operational Information Cancelled
Aug 25, 2024 9:19:29 AM The SASM scheduled for 09:40 has been changed to execute 0950 for operating day 08/25/24 for HE 12-24 for 38 MW of ECRS for each hour. Operational Information Active
Aug 25, 2024 9:11:24 AM ERCOT will execute a SASM at 0940 for operating day 08/25/24 for HE 12-24 for 38 MW of ECRS for each hour. Operational Information Active
Aug 25, 2024 8:46:26 AM The Daily RSASM for 08/25/2024 will not be occurring due to zero participating QSEs. Operational Information Active
Aug 25, 2024 12:00:55 AM No sudden loss of generation greater than 450 MW occurred on August 24, 2024. Operational Information Active
Aug 24, 2024 8:46:49 AM The Daily RSASM for 08/24/2024 will not be occurring due to zero participating QSEs. Operational Information Active
Aug 24, 2024 12:04:13 AM No sudden loss of generation greater than 450 MW occurred on August 23, 2024. Operational Information Active
Aug 23, 2024 3:54:08 PM Market price correction for SCED. ERCOT has identified a need to perform a price correction for Real-Time Settlement Interval 00:15 on Operating Day 8/23/2024. This was due to Emergency Basepoints being automatically activated during scheduled system maintenance. ERCOT has determined that the impact to Real-Time Meter Prices (RTRMPRs) meets criteria for price correction in accordance with ERCOT Protocol Section 6.3(5). Corrections to RTRMPRs will be finished by 16:00 on 08/27/2024. Since ERCOT does not post price corrections for RTRMPRs, this price correction will be reflected on the settlement statements of the impacted QSEs. Alert Active
Aug 23, 2024 8:53:24 AM The Daily RSASM for 08/23/2024 will not be occurring due to zero participating QSEs. Operational Information Active
Aug 23, 2024 12:29:28 AM No sudden loss of generation greater than 450 MW occurred on August 22, 2024. Operational Information Active
Aug 23, 2024 12:13:19 AM ERCOT Emergency Base Points are Disabled Operational Information Cancelled
Aug 23, 2024 12:02:23 AM ERCOT Emergency Base Points are Enabled Operational Information Active
Aug 22, 2024 6:04:41 PM ERCOT has cancelled the following notice: At 15:36 ERCOT will perform an EMS migration on its Energy & Market Management Systems. In the event ICCP is suspended, all systems should re-establish automatically within a few minutes. Operational Information Cancelled
Aug 22, 2024 4:20:27 PM Update Notice for Real-Time Market (RTM) price correction. This is an update to the RTM price correction notice posted on 08/22/2024 at 1:15 PM. ERCOT was unable to meet the posting deadline for correcting prices. A follow-up Market Notice will be issued with further information. Alert Active
Aug 22, 2024 2:31:43 PM At 15:36 ERCOT will perform an EMS migration on its Energy & Market Management Systems. In the event ICCP is suspended, all systems should re-establish automatically within a few minutes. Operational Information Active
Aug 22, 2024 1:15:28 PM Real-Time Market (RTM) price correction. ERCOT has identified a need to perform a price correction for the Real-Time Settlement Interval 20:45 on Operating Day 08/20/2024. This is due to a software error in an EMS application that inadvertently triggered a premature recall of an ERCOT Contingency Reserve Service (ECRS) deployment. Price Correction data will be posted to the ERCOT MIS by 16:00 on 08/22/2024. Alert Active
Aug 22, 2024 12:03:47 PM ERCOT has cancelled the following notice: ERCOT will execute a SASM at 1150 for operating day 08/22/24 for HE 14 for 130.8 MW of ECRS and for HE 15 117.5 MW ECRS and 2.5 MW RRS Operational Information Cancelled
Aug 22, 2024 11:19:23 AM ERCOT will execute a SASM at 1150 for operating day 08/22/24 for HE 14 for 130.8 MW of ECRS and for HE 15 117.5 MW ECRS and 2.5 MW RRS Operational Information Active
Aug 22, 2024 8:47:00 AM The Daily RSASM for 08/22/2024 will not be occurring due to zero participating QSEs. Operational Information Active
Aug 22, 2024 8:37:48 AM ERCOT has cancelled the following notice: ERCOT will execute a SASM at 0815 for operating day 08/22/24 for HE 11 for 79.8 MW ECRS and 55.2 MW RRS. Operational Information Cancelled
Aug 22, 2024 7:37:55 AM ERCOT will execute a SASM at 0815 for operating day 08/22/24 for HE 11 for 79.8 MW ECRS and 55.2 MW RRS. Operational Information Active
Aug 22, 2024 12:11:04 AM No sudden loss of generation greater than 450 MW occurred on August 21, 2024. Operational Information Active
Aug 21, 2024 4:51:52 PM Frequency Measurable Events: Report tracking Frequency Measurable Events (FMEs) as of 08/21/2024 is available. Operational Instruction Active
Aug 21, 2024 8:46:41 AM The Daily RSASM for 08/21/2024 will not be occurring due to zero participating QSEs. Operational Information Active
Aug 21, 2024 12:18:38 AM No sudden loss of generation greater than 450 MW occurred on August 20, 2024. Operational Information Active
Aug 20, 2024 10:10:43 PM ERCOT has cancelled the following notice: ERCOT is issuing an OCN for the extreme hot weather with forecasted temperatures to be at or above 103°F in the North-Central and South-Central weather zones from Sunday, August 18, 2024 through Tuesday, August 20, 2024. OCN Cancelled
Aug 20, 2024 9:10:48 PM At 21:10, All Non-Spin has been recalled. Operational Information Active
Aug 20, 2024 9:10:03 PM CM-ASM-NOTF AS_TYPE: Non-Spin, DEPLOY_MW: 0.0, BEGIN_TIME: 2024-08-20 21:10:03, END_TIME: 2024-08-20 21:10:03, DURATION: 0 Hrs 0 Mins.; Operational Information
Aug 20, 2024 8:45:40 PM ERCOT ECRS HAS BEEN RECALLED Operational Information Cancelled
Aug 20, 2024 8:33:02 PM CM-ASM-NOTF AS_TYPE: Non-Spin, DEPLOY_MW: 571.4, BEGIN_TIME: 2024-08-20 21:00:00, END_TIME: 2024-08-20 23:59:59, DURATION: 2 Hrs 59 Mins.; Operational Information
Aug 20, 2024 8:30:48 PM ERCOT ECRS HAS BEEN DEPLOYED Operational Information Active
Aug 20, 2024 8:28:44 PM ERCOT ECRS HAS BEEN RECALLED Operational Information Cancelled
Aug 20, 2024 7:33:02 PM CM-ASM-NOTF AS_TYPE: Non-Spin, DEPLOY_MW: 600.5, BEGIN_TIME: 2024-08-20 20:00:00, END_TIME: 2024-08-20 23:59:59, DURATION: 3 Hrs 59 Mins.; Operational Information
Aug 20, 2024 7:26:00 PM ERCOT ECRS HAS BEEN DEPLOYED Operational Information Active
Aug 20, 2024 6:37:24 PM At 18:36 approximately 598.5 MW of Non-Spin has been deployed, anticipated duration is 23:59. Operational Information Active
Aug 20, 2024 6:36:16 PM CM-ASM-NOTF AS_TYPE: Non-Spin, DEPLOY_MW: 598.5, BEGIN_TIME: 2024-08-20 18:36:16, END_TIME: 2024-08-20 23:59:59, DURATION: 5 Hrs 23 Mins.; Operational Information
Aug 20, 2024 8:49:03 AM The Daily RSASM for 08/20/2024 will not be occurring due to zero participating QSEs. Operational Information Active
Aug 20, 2024 1:48:54 AM The minimum monthly Ancillary Services quantities have been posted to the ERCOT Website; Data Products; Grid; Forecasts under the Projected Ancillary Service Requirements link located under the Reports & Extracts heading. The posted quantities reflect minimum requirements only. ERCOT will follow-up with a Notification if any upward adjustments to these minimum quantities are made. https://mis.ercot.com/secure/data-products/grid/forecasts AS Postings Active
Aug 20, 2024 12:11:54 AM No sudden loss of generation greater than 450 MW occurred on August 19, 2024. Operational Information Active
Aug 19, 2024 8:48:26 AM The Daily RSASM for 08/19/2024 will not be occurring due to zero participating QSEs. Operational Information Active
Aug 19, 2024 12:06:46 AM No sudden loss of generation greater than 450 MW occurred on August 18, 2024. Operational Information Active
Aug 18, 2024 8:24:32 PM CM-ASM-NOTF AS_TYPE: Non-Spin, DEPLOY_MW: 0.0, BEGIN_TIME: 2024-08-18 20:24:32, END_TIME: 2024-08-18 20:24:32, DURATION: 0 Hrs 0 Mins.; Operational Information
Aug 18, 2024 8:21:09 PM At 20:20, All Non-Spin has been recalled. Operational Information Active
Aug 18, 2024 8:20:07 PM CM-ASM-NOTF AS_TYPE: Non-Spin, DEPLOY_MW: 370.1, BEGIN_TIME: 2024-08-18 20:20:07, END_TIME: 2024-08-18 23:59:59, DURATION: 3 Hrs 39 Mins.; Operational Information
Aug 18, 2024 7:33:01 PM CM-ASM-NOTF AS_TYPE: Non-Spin, DEPLOY_MW: 437.0, BEGIN_TIME: 2024-08-18 20:00:00, END_TIME: 2024-08-18 23:59:59, DURATION: 3 Hrs 59 Mins.; Operational Information
Aug 18, 2024 6:53:09 PM At 18:51 approximately 368 MW of Non-Spin has been deployed, anticipated duration is 2359. Operational Information Active
Aug 18, 2024 6:51:55 PM CM-ASM-NOTF AS_TYPE: Non-Spin, DEPLOY_MW: 368.0, BEGIN_TIME: 2024-08-18 18:51:54, END_TIME: 2024-08-18 23:59:59, DURATION: 5 Hrs 8 Mins.; Operational Information
Aug 18, 2024 3:04:08 PM ERCOT has cancelled the following notice: ERCOT will execute a SASM at 14:45 for operating day 08/18/24 for ECRS, 14.4 MW for HE17, 19 MW for HE18, and for REGUP, 9 MW for HE19 Operational Information Cancelled
Aug 18, 2024 2:07:39 PM ERCOT will execute a SASM at 14:45 for operating day 08/18/24 for ECRS, 14.4 MW for HE17, 19 MW for HE18, and for REGUP, 9 MW for HE19 Operational Information Active
Aug 18, 2024 8:49:03 AM The Daily RSASM for 08/18/2024 will not be occurring due to zero participating QSEs. Operational Information Active
Aug 18, 2024 12:01:35 AM No sudden loss of generation greater than 450 MW occurred on August 17, 2024. Operational Information Active
Aug 17, 2024 8:02:34 PM ERCOT has cancelled the following notice: The Space Weather Prediction Center has issued a GMD Warning of K7 until August 17, 2024 until 2000 CST. Advisory Cancelled
Aug 17, 2024 8:02:27 PM ERCOT has cancelled the following notice: The Space Weather Prediction Center has issued the GMD ALERT of K7 at 13:00, August 17, 2024. Advisory Cancelled
Aug 17, 2024 1:24:09 PM The Space Weather Prediction Center has issued the GMD ALERT of K7 at 13:00, August 17, 2024. Advisory Active
Aug 17, 2024 1:13:09 PM The Space Weather Prediction Center has issued a GMD Warning of K7 until August 17, 2024 until 2000 CST. Advisory Active
Aug 17, 2024 8:47:09 AM The Daily RSASM for 08/17/2024 will not be occurring due to zero participating QSEs. Operational Information Active
Aug 17, 2024 12:45:37 AM No sudden loss of generation greater than 450 MW occurred on August 16, 2024. Operational Information Active
Aug 16, 2024 10:00:06 AM ERCOT is issuing an OCN for the extreme hot weather with forecasted temperatures to be at or above 103°F in the North-Central and South-Central weather zones from Sunday, August 18, 2024 through Tuesday, August 20, 2024. OCN Active
Aug 16, 2024 8:46:56 AM The Daily RSASM for 08/16/2024 will not be occurring due to zero participating QSEs. Operational Information Active
Aug 16, 2024 12:01:13 AM No sudden loss of generation greater than 450 MW occurred on August 15, 2024. Operational Information Active
Aug 15, 2024 8:46:32 AM The Daily RSASM for 08/15/2024 will not be occurring due to zero participating QSEs. Operational Information Active
Aug 15, 2024 12:00:29 AM No sudden loss of generation greater than 450 MW occurred on August 14, 2024. Operational Information Active
Aug 14, 2024 8:52:34 AM The Daily RSASM for 08/14/2024 will not be occurring due to zero participating QSEs. Operational Information Active
Aug 14, 2024 12:07:11 AM No sudden loss of generation greater than 450 MW occurred on August 13, 2024. Operational Information Active
Aug 13, 2024 8:49:12 AM The Daily RSASM for 08/13/2024 will not be occurring due to zero participating QSEs. Operational Information Active
Aug 13, 2024 12:15:20 AM ERCOT has cancelled the following notice: ERCOT will execute a SASM at 23:50 for operating day 08/13/2024 for 38 MW ECRS for HE 2-8. Operational Information Cancelled
Aug 13, 2024 12:00:55 AM No sudden loss of generation greater than 450 MW occurred on August 12, 2024. Operational Information Active
Aug 12, 2024 11:09:30 PM ERCOT will execute a SASM at 23:50 for operating day 08/13/2024 for 38 MW ECRS for HE 2-8. Operational Information Active
Aug 12, 2024 7:00:48 PM ERCOT has cancelled the following notice: The Space Weather Prediction Center has extended the GMD Warning of K7 on August 12, 2024 from 13:00 Central time until 19:00 Central time. Operational Information Cancelled
Aug 12, 2024 7:00:36 PM ERCOT has cancelled the following notice: The Space Weather Prediction Center has extended the GMD Warning of K7 on August 12, 2024 from 04:00 Central time until 10:00 Central time. Operational Information Cancelled
Aug 12, 2024 7:00:23 PM ERCOT has cancelled the following notice: The Space Weather Prediction Center has issued a GMD ALERT of K7 beginning August 12, 2024 at 05:25. Advisory Cancelled
Aug 12, 2024 1:00:07 PM ERCOT has cancelled the following notice: The Space Weather Prediction Center has extended the GMD Warning of K7 on August 12, 2024 from 10:00 Central time until 13:00 Central time. Operational Information Cancelled
Aug 12, 2024 12:56:52 PM The Space Weather Prediction Center has extended the GMD Warning of K7 on August 12, 2024 from 13:00 Central time until 19:00 Central time. Operational Information Active
Aug 12, 2024 9:37:10 AM The Space Weather Prediction Center has extended the GMD Warning of K7 on August 12, 2024 from 10:00 Central time until 13:00 Central time. Operational Information Active
Aug 12, 2024 8:48:10 AM The Daily RSASM for 08/12/2024 will not be occurring due to zero participating QSEs. Operational Information Active
Aug 12, 2024 4:18:56 AM ERCOT has cancelled the following notice: CORRECTION: The Space Weather Prediction Center has issued a GMD Warning of K7 until August 12, 2024 beginning 00:00 Central time till 04:00 Central time. Operational Information Cancelled
Aug 12, 2024 4:18:48 AM The Space Weather Prediction Center has extended the GMD Warning of K7 on August 12, 2024 from 04:00 Central time until 10:00 Central time. Operational Information Active
Aug 12, 2024 1:30:08 AM ERCOT has cancelled the following notice: The Space Weather Prediction Center has issued a GMD Warning of G7 until August 12, 2024 beginning 00:00 Central time till 04:00 Central time. Operational Information Cancelled
Aug 12, 2024 1:29:56 AM CORRECTION: The Space Weather Prediction Center has issued a GMD Warning of K7 until August 12, 2024 beginning 00:00 Central time till 04:00 Central time. Operational Information Active
Aug 12, 2024 1:03:20 AM No sudden loss of generation greater than 450 MW occurred on August 11, 2024. Operational Information Active
Aug 12, 2024 12:45:46 AM The Space Weather Prediction Center has issued a GMD ALERT of K7 beginning August 12, 2024 at 05:25. Advisory Active
Aug 12, 2024 12:26:17 AM The Space Weather Prediction Center has issued a GMD Warning of G7 until August 12, 2024 beginning 00:00 Central time till 04:00 Central time. Operational Information Active
Aug 11, 2024 8:47:19 AM The Daily RSASM for 08/11/2024 will not be occurring due to zero participating QSEs. Operational Information Active
Aug 11, 2024 12:13:28 AM On 8/10/2024, a sudden loss of generation occurred at 02:56 totaling 654 MW. Frequency declined to 59.911 Hz, ERCOT load was 52,858 MW. Operational Information Active
Aug 10, 2024 5:37:56 PM ERCOT has cancelled the following notice: ERCOT will execute a SASM at 17:10 for operating day 08/10/24 for HE 20-22, 10 MW ECRS each hour Operational Information Cancelled
Aug 10, 2024 4:41:22 PM ERCOT will execute a SASM at 17:10 for operating day 08/10/24 for HE 20-22, 10 MW ECRS each hour Operational Information Active
Aug 10, 2024 8:47:20 AM The Daily RSASM for 08/10/2024 will not be occurring due to zero participating QSEs. Operational Information Active
Aug 10, 2024 12:13:30 AM No sudden loss of generation greater than 450 MW occurred on August 9, 2024. Operational Information Active
Aug 9, 2024 10:42:00 PM ERCOT has cancelled the following notice: ERCOT will execute a SASM at 22:10 for operating day 08/10/24 for NON-SPIN HE01-HE02 for 14.2 MW, HE01 and 17.9 MW, HE02 Operational Information Cancelled
Aug 9, 2024 9:39:05 PM ERCOT will execute a SASM at 22:10 for operating day 08/10/24 for NON-SPIN HE01-HE02 for 14.2 MW, HE01 and 17.9 MW, HE02 Operational Information Active
Aug 9, 2024 3:24:21 PM ERCOT has cancelled the following notice: ERCOT will execute a SASM at 14:50 for operating day 08/09/2024 for 72 MW RegUP HE 20, 26.9 MW RegDN HE 17, 7 MW RegDN HE 21, 16.7 MW RRS HE 17-18, 37 MW RRS HE 19, 55.6 MW RRS HE 21, 67.5 MW RRS HE 22, 70.3 MW ECRS HE 17, 89 MW ECRS HE 18, 87.6 MW ECRS HE 19, 89 MW ECRS HE 20, 39.1 MW ECRS HE 21, and 42.2 MW ECRS HE 22. Operational Information Cancelled
Aug 9, 2024 2:24:25 PM ERCOT will execute a SASM at 14:50 for operating day 08/09/2024 for 72 MW RegUP HE 20, 26.9 MW RegDN HE 17, 7 MW RegDN HE 21, 16.7 MW RRS HE 17-18, 37 MW RRS HE 19, 55.6 MW RRS HE 21, 67.5 MW RRS HE 22, 70.3 MW ECRS HE 17, 89 MW ECRS HE 18, 87.6 MW ECRS HE 19, 89 MW ECRS HE 20, 39.1 MW ECRS HE 21, and 42.2 MW ECRS HE 22. Operational Information Active
Aug 9, 2024 1:16:19 PM ERCOT has cancelled the following notice: ERCOT will execute a SASM at 12:50 for operating day 08/09/2024 for 89 MW ECRS HE 15-16. Operational Information Cancelled
Aug 9, 2024 12:14:01 PM ERCOT will execute a SASM at 12:50 for operating day 08/09/2024 for 89 MW ECRS HE 15-16. Operational Information Active
Aug 9, 2024 11:10:03 AM ERCOT has cancelled the following notice: ERCOT will execute a SASM at 10:50 for operating day 08/09/2024 for 51.5 MW ECRS HE 13, 89 MW ECRS HE14, 35.6 MW RegDN HE 13-14, 55.3 MW RegUP HE 13, and 17.8 MW RegUP HE 14. Operational Information Cancelled
Aug 9, 2024 10:14:12 AM ERCOT will execute a SASM at 10:50 for operating day 08/09/2024 for 51.5 MW ECRS HE 13, 89 MW ECRS HE14, 35.6 MW RegDN HE 13-14, 55.3 MW RegUP HE 13, and 17.8 MW RegUP HE 14. Operational Information Active
Aug 9, 2024 8:46:38 AM The Daily RSASM for 08/09/2024 will not be occurring due to zero participating QSEs. Operational Information Active
Aug 9, 2024 4:00:36 AM ERCOT will be working from the primary control center until further notice, use the OPX numbers for Taylor. Operational Information Active
Aug 9, 2024 3:57:46 AM ERCOT has cancelled the following notice: ERCOT will be working from the alternate control center until further notice, use the OPX numbers for Bastrop. Operational Information Cancelled
Aug 9, 2024 12:19:00 AM No sudden loss of generation greater than 450 MW occurred on August 8, 2024. Operational Information Active
Aug 8, 2024 8:39:59 PM ERCOT has cancelled the following notice: ERCOT is issuing an OCN for the extreme hot weather with forecasted temperatures to be above 103°F in the North Central and South Central weather zones from Wednesday, August 7, 2024 through Thursday, August 8, 2024. OCN Cancelled
Aug 8, 2024 3:50:44 PM ERCOT will be working from the alternate control center until further notice, use the OPX numbers for Bastrop. Operational Information Active
Aug 8, 2024 11:12:38 AM ERCOT has cancelled the following notice: ERCOT will execute a SASM at 10:50 for operating day 08/08/2024 for 1.3 MW ECRS HE 16-19. Operational Information Cancelled
Aug 8, 2024 10:17:51 AM ERCOT will execute a SASM at 10:50 for operating day 08/08/2024 for 1.3 MW ECRS HE 16-19. Operational Information Active
Aug 8, 2024 8:46:39 AM The Daily RSASM for 08/08/2024 will not be occurring due to zero participating QSEs. Operational Information Active
Aug 8, 2024 1:02:48 AM ERCOT has cancelled the following notice: ERCOT will execute a SASM at 00:45 for operating day 08/08/2024 for 33.7 MW ECRS HE 03-07 Operational Information Cancelled
Aug 8, 2024 12:40:07 AM On 08/07/2024, a sudden loss of generation occurred at 17:56 totaling 624 MW. Frequency declined to 59.938 Hz, ERCOT load was 83,684 MW. Operational Information Active
Aug 8, 2024 12:03:08 AM ERCOT will execute a SASM at 00:45 for operating day 08/08/2024 for 33.7 MW ECRS HE 03-07 Operational Information Active
Aug 7, 2024 11:15:10 PM ERCOT has cancelled the following notice: ERCOT will execute a SASM at 22:50 for operating day 08/08/2024 for 38 MW ECRS HE 01-07 Operational Information Cancelled
Aug 7, 2024 10:17:18 PM ERCOT will execute a SASM at 22:50 for operating day 08/08/2024 for 38 MW ECRS HE 01-07 Operational Information Active
Aug 7, 2024 8:16:01 PM At 20:15, All Non-Spin has been recalled. Operational Information Active
Aug 7, 2024 8:15:17 PM CM-ASM-NOTF AS_TYPE: Non-Spin, DEPLOY_MW: 0.0, BEGIN_TIME: 2024-08-07 20:15:17, END_TIME: 2024-08-07 20:15:17, DURATION: 0 Hrs 0 Mins.; Operational Information
Aug 7, 2024 7:33:01 PM CM-ASM-NOTF AS_TYPE: Non-Spin, DEPLOY_MW: 156.0, BEGIN_TIME: 2024-08-07 20:00:00, END_TIME: 2024-08-07 23:59:59, DURATION: 3 Hrs 59 Mins.; Operational Information
Aug 7, 2024 7:15:52 PM CM-ASM-NOTF AS_TYPE: Non-Spin, DEPLOY_MW: 154.0, BEGIN_TIME: 2024-08-07 19:15:52, END_TIME: 2024-08-07 23:59:59, DURATION: 4 Hrs 44 Mins.; Operational Information
Aug 7, 2024 7:15:16 PM At 19:13 approximately 153.95 MW of Non-Spin has been deployed, anticipated duration is 23:59:59. Operational Information Active
Aug 7, 2024 7:13:52 PM CM-ASM-NOTF AS_TYPE: Non-Spin, DEPLOY_MW: 154.0, BEGIN_TIME: 2024-08-07 19:13:51, END_TIME: 2024-08-07 20:00:00, DURATION: 0 Hrs 46 Mins.; Operational Information
Aug 7, 2024 8:47:55 AM The Daily RSASM for 08/07/2024 will not be occurring due to zero participating QSEs. Operational Information Active
Aug 7, 2024 12:15:01 AM No sudden loss of generation greater than 450 MW occurred on August 6, 2024. Operational Information Active
Aug 6, 2024 1:05:23 PM ERCOT is issuing an OCN for the extreme hot weather with forecasted temperatures to be above 103°F in the North Central and South Central weather zones from Wednesday, August 7, 2024 through Thursday, August 8, 2024. OCN Active
Aug 6, 2024 8:48:40 AM The Daily RSASM for 08/06/2024 will not be occurring due to zero participating QSEs. Operational Information Active
Aug 6, 2024 1:21:58 AM No sudden loss of generation greater than 450 MW occurred on August 5, 2024. Operational Information Active
Aug 5, 2024 8:48:28 AM The Daily RSASM for 08/05/2024 will not be occurring due to zero participating QSEs. Operational Information Active
Aug 5, 2024 12:13:45 AM No sudden loss of generation greater than 450 MW occurred on August 4, 2024. Operational Information Active
Aug 4, 2024 1:00:56 PM ERCOT has cancelled the following notice: The Space Weather Prediction Center has issued a GMD Warning of K-7 or greater until August 4, 2024 13:00. Operational Information Cancelled
Aug 4, 2024 1:00:35 PM ERCOT has cancelled the following notice: The Space Weather Prediction Center has issued a GMD Alert of K-7 or greater until August 4, 2024 0700-1000. Operational Information Cancelled
Aug 4, 2024 10:13:54 AM The Space Weather Prediction Center has issued a GMD Alert of K-7 or greater until August 4, 2024 0700-1000. Operational Information Active
Aug 4, 2024 10:03:57 AM The Space Weather Prediction Center has issued a GMD Warning of K-7 or greater until August 4, 2024 13:00. Operational Information Active
Aug 4, 2024 8:45:58 AM The Daily RSASM for 08/04/2024 will not be occurring due to zero participating QSEs. Operational Information Active
Aug 4, 2024 12:00:02 AM No sudden loss of generation greater than 450 MW occurred on August 3, 2024. Operational Information Active
Aug 3, 2024 8:46:07 AM The Daily RSASM for 08/03/2024 will not be occurring due to zero participating QSEs. Operational Information Active
Aug 3, 2024 12:04:24 AM No sudden loss of generation greater than 450 MW occurred on August 2, 2024. Operational Information Active
Aug 2, 2024 10:55:01 PM ERCOT has cancelled the following notice: ERCOT will execute a SASM at 21:50 for operating day 08/03/2024 for 4.6 MW ECRS HE 01-14, 5.9 MW ECRS HE 15-19, 5.6 MW ECRS HE 20, 4.6 MW ECRS HE 21-24. Operational Information Cancelled
Aug 2, 2024 9:14:01 PM ERCOT will execute a SASM at 21:50 for operating day 08/03/2024 for 4.6 MW ECRS HE 01-14, 5.9 MW ECRS HE 15-19, 5.6 MW ECRS HE 20, 4.6 MW ECRS HE 21-24. Operational Information Active
Aug 2, 2024 8:46:14 AM The Daily RSASM for 08/02/2024 will not be occurring due to zero participating QSEs. Operational Information Active
Aug 2, 2024 12:14:01 AM No sudden loss of generation greater than 450 MW occurred on August 1, 2024. Operational Information Active
Aug 1, 2024 8:45:56 AM The Daily RSASM for 08/01/2024 will not be occurring due to zero participating QSEs. Operational Information Active
Aug 1, 2024 3:56:58 AM ERCOT will be working from the primary control center until further notice, use the OPX numbers for Taylor. Operational Information Active
Aug 1, 2024 12:00:58 AM No sudden loss of generation greater than 450 MW occurred on July 31, 2024. Operational Information Active